| Test CODE | NAME | 
|---|
X443
D-Dimer
| Methodology: | Turbidimetric immunoassay | 
| Performed: | Sun-Sat | 
| Reported: | 24 hours | 
| Specimen Required: | Collect:  Sodium citrate 3.2% (Light Blue-top) tube - 1 ml plasma
 
 Specimen Preparation: Draw blood into a light blue top tube containing 3.2% sodium citrate. Fill to the proper level, indicated by a fill line on the tube. Gently invert six times to mix. Centrifuge the citrated blue-top tubes as soon as possible (within 60 minutes) at adequate time and speed to obtain platelet-poor plasma (<10,000/µL). Using a plastic pipette, remove 1 mL of plasma and transfer to a plastic aliquot tube and label with patient's name and a second patient identifier (e.g., date of birth, medical record number).
 
Storage/Transport Temperature: CRITICAL FROZEN.  
Separate specimens must be submitted when multiple tests are ordered. 
Unacceptable Conditions: Serum. EDTA plasma, or hemolyzed specimens. 
Stability: After separation from cells: Room Temperature: 2 hrs; Refrigerated: Unacceptable; Frozen: 30 days   
Reject Criteria:  Gross hemolysis  Gross lipemia  Clotted specimens  Improper blood to citrate ratio  Improper tube type  Mislabeled specimen  Specimen received without identifiers  Frozen, unspun whole blood collection  Non-frozen plasma specimens received > 2 hours after collection
NOTE: * This test is approved for all states. * Accu Reference Medical Laboratory  | 
| CPT Code(s): | 85379 |