Q209

Test CODE NAME

Q209

Fluoride Quantitative, Serum or Plasma

Methodology: Quantitative Ion Chromatography (Ion Exchange Chromatography)
Performed: Sun-Sat
Reported: 4-10 days
Specimen Required: Collect: Plain Red OR Lavender (EDTA) - 2 ml serum or plasma.
Specimen Preparation: Allow specimen to clot completely at room temperature. Separate from cells within 2 hours. Transfer  serum or plasma to a Standard Transport Tube. 
Storage/Transport Temperature: Refrigerated.
Unacceptable Conditions: Gray (potassium oxalate/sodium fluoride) or separator tubes.
Stability: Refrigerated: 1 week; Frozen: 1 month   
Note: This test is approved for NY . 
Performing Lab 
ARUP Laboratory
CPT Code(s): 82735