L654

Test CODE NAME

L654

Magnesium RBC

Methodology: Atomic absorption spectrometry (AAS); inductively-coupled plasma/mass spectrometry (ICP/MS)
Performed: Mon-Sat
Reported: 2-4 days
Specimen Required:
Collect: Green-top (heparin) tube OR lavender-top (EDTA) tube OR Royal blue-top (EDTA) tube - 1 ml Red blood cells (RBCs)

Specimen Preparation: Centrifuge tube within 45 minutes of collection and separate plasma from cells. Discard the plasma. Using the original collection tube, submit only the RBCs to the laboratory.

Storage/Transport Temperature:    Room temperature 
Stability: Room Temperature/Refrigerated:1 week

Causes for Rejection : Serum or plasma specimen


NOTE: * This test is approved for all states. * 
Performing Laboratory
Laboratory Corporation of America®
CPT Code(s): 83735