Test CODE | NAME |
---|
344
Myocardial Antibody, IgG with Reflex to Titer
Methodology: | Semi-Quantitative Indirect Fluorescent Antibody |
Performed: | Mon-Fri |
Reported: | 2-5 days |
Specimen Required: | Collect: Serum Separator Tube (SST) - 1 ml serum.
Specimen Preparation: Allow specimen to clot completely at room temperature . Separate serum from cells ASAP or within 2 hours of collection.
Storage/Transport Temperature: Refrigerated.
Unacceptable Conditions: Plasma. Contaminated, hemolyzed, or severely lipemic specimens.
Stability: After separation from cells: Ambient: 48 hours; Refrigerated: 1 week; Frozen: 1 month (avoid repeated freeze/thaw cycles)
Note: This test is approved for NY .
Performing Lab
ARUP Laboratory
|
CPT Code(s): | 86255; if reflexed, add 86256 |