Test CODE | NAME |
---|
M138
Polyomavirus BK by Real-Time PCR
Methodology: | Real-Time PCR |
Performed: | Sun-Sat |
Reported: | 3-4 days |
Specimen Required: |
Collect: UroSwab® (males), whole blood yellow top tube (ACD solution A) Specimen Preparation: Whole Blood Collection vessel: Yellow top tube (ACD solution A) Volume: Complete . Completely fill the tube whenever possible to eliminate dilution from the anticoagulant and ensure the proper blood-to-anticoagulant ratio. Collection Notes: Immediately after blood collection, invert the tube(s) gently 8-10 times to ensure mixing of anticoagulant with blood to prevent clotting. Do not shake tube(s). Do not centrifuge specimen. UroSwab® Collection vessel: Complete 1 Step. Urine collection should be at least one hour between voids. 2 Step. Have the patient collect a urine sample in a urine container. 3 Step. Dip the sponge into the urine container. 4 Step. Place the sponge into the vial. To prevent leakage , tightly cap the vial. Label with a minimum of two patients identifiers such as name and date of birth. Storage/Transport Temperature: Room Temperature. Stability : Refrigerated: 1 week; Frozen: 1 month NOTE: * This test is approved for all states. * Performing Laboratory MDL (Molecular Diagnostics Laboratories) |
CPT Code(s): | 87799 |