0993

Test CODE NAME

0993

Vitamin C (Ascorbic Acid), Plasma0993Vitamin C (Ascorbic Acid), Plasma

Methodology: High performance liquid chromatography (HPLC)
Performed: Mon., Thu.
Reported: 3-5 days
Specimen Required: Collect: Green (sodium or lithium heparin) - 0.5 ml plasma.
Specimen Preparation: Centrifuge, transfer plasma and freeze within 1 hour of collection. Transfer  plasma to a Amber Transport Tube. 
Storage/Transport Temperature: CRITICAL FROZEN AND LIGHT PROTECTED. 
Unacceptable Conditions: EDTA plasma, whole blood, or body fluids. Remarks: Thawing and refreezing of the specimen and exposure to light will result in decreased Vitamin C concentration. 
Stability: After separation from cells: Ambient: Unacceptable; Refrigerated: Unacceptable; Frozen: 1 moth 
NOTE: *This test is not available for New York patients, please refer to test code 993 OR L014 for specimen requirements .* 
Performing Lab
Accu Reference Medical Laboratory
CPT Code(s): 86003
Methodology: Quantitative High Performance Liquid Chromatography
Performed: Mon-Fri
Reported: 3-5 days
Specimen Required: Collect: Green (sodium or lithium heparin). Place specimen in ice bath immediately - 1.0  ml plasma. 
Specimen Preparation: Protect from light, centrifuge, transfer plasma and freeze within 1 hour of collection. Transfer  to an  Amber Transport Tube. 
Storage/Transport Temperature: CRITICAL FROZEN AND LIGHT PROTECTED. 
Separate specimens must be submitted when multiple tests are ordered Unacceptable Conditions: EDTA plasma, whole blood, or body fluids. Grossly hemolyzed specimens.  
Remarks: Thawing and refreezing of the specimen and exposure to light will result in decreased Vitamin C concentration. 
Stability: After separation from cells: Ambient: Unacceptable; Refrigerated: Unacceptable; Frozen: 1 month
NOTE: * This test is not available for New York patients, please refer to test code Q726 for specimen requirements.*
Performing Laboratory
Accu Reference Medical Laboratory
CPT Code(s): 82180